Laserfiche WebLink
• . ADMINlSTRATION <br /> SECTION R1 Q5 4. Steam,hot or chilled water piping within any heating or <br /> PERMITS coolin�equipment re�ulated by this code. <br /> R1Q5.1 Required.Any owner or authorized agent who intends 5. Replacement of any minor part that does not alter <br /> to construct, enlar�e, alter, repair, move, demolish or chanbe approva]of equipment or make such equipment unsafe. <br /> the occupancy of a building or structure, or to erect, install, <br /> enlarge,alter,repair,remove,convert or replace any electrical, 6. Portable evaporative coolers. <br /> gas.mechanical or plumbing system, the ins�allation of which 7. Self-contained refrigeration systems containing 10 <br /> is re�ulated by this code,or to cause any such work to be done, pounds(4.54 k�)ar less of refrigerant or that are actuated <br /> shall first make application to the building ofFicial and obtain by motors of 1 horsepower(746 W)or less. <br /> the required permit. 8, portable-fuel-cell appliances that are not connected to a <br /> R10�.2 Work exempt from permit. Permits shall not be fixed pipin� system and are not interconnected to a <br /> required for the followinb. Exemption from permit require- power�rid. <br /> ments of this code shall not be deemed to grant authorization <br /> for any work to be done in any manner in violation of the provi- The stoppin�of leaks in drains,water,soil,waste or vent pipe; <br /> sions of this code or any other laws or ordinances of this provided,however,that if any concealed trap.drainpipe,water, <br /> jurisdiction. soil,waste or vent pipe hecomes defective and it becomes nec- <br /> essar5�to remove and replace the same with new material,such <br /> Building: work shall be considered as new work and a permit shall be <br /> 1. One-story detached accessory structures used as tool and obtained and inspection made as provided in this code. <br /> storage sheds,playhouses and similar uses,provided the The clearing of stoppa=es or the repairing of leaks in pipes, <br /> floor area does not exceed 120 square feet(11.15 mz). valves or fixtures, and the removal and reinstallation of water <br /> 2. Fences not over 6 feet(1829 mm)high. closets, provided such repairs do not invo]ve or require the <br /> 3. Retaining walls that are not over 4 feet (]219 mm) in replacement or rearrangement of valves,pipes or fixtures. <br /> hei�ht measured from the bottom of the footin�to the top Rl(l5.2.1 Emergency repairs. Where equipment replace- <br /> of the wall,unless supporting a surcharge. ments and repairs must be performed in an emergency situa- <br /> 4. Water tanks supported directly u}�on grade if the capacity tion, the permit application shall be submitted within the <br /> does not exceed 5,000 gallons(l 8 927 L)and the ratio of next working business day to the building official. <br /> hei�ht to diameter or width does not exceed 2 to 1. R1Q5.2.2 Repairs. Application or notice to the buildin� <br /> � 5. Side�vall<s and driveways. ofFicial is not required for- ordina�y repairs to structares, <br /> 6. Paintin�, papering, tiling, carpetin�, cabinets, counter replacement of lamps ar the connection of approved porta- <br /> tops and similar finish work. ble electrical equipment to approved permanently installed <br /> receptacles.Such repairs shall not include the cutting away <br /> 7. Prefabricated swimming pools that are less than 24 of any wall,partition or portion thereof,the removal or cut- <br /> inches(6l0 mm)deep. tinD of any structural beam or load-bearing support, or the <br /> � 8. Swings and other playground equipment. removal or change of any required means oi egress,or rear- <br /> 9. Window awnin�s supported by an exterior wall which rangement of parts of a structure affectinD the e�ress <br /> do not project more than 54 inc}�es(1372 mm)from the requirements:nor shall ordinary repairs include addition to, <br /> exterior wall and do not require additional support. alteration of,replacement or relocation of any water supply, <br /> sewer, drainage,drain leader,gas, soil,waste,venl or simi- <br /> Eiectrica�: ]ar piping, electric wiring or mechanical or other worlc <br /> Repairs and maintenance: A permit sha11 not be required for affecting public health or general safery. <br /> minor repair work, includin�the replacement of lamps or the R105.2.3 Public service agencies. A permit shall not be <br /> connection of approved portable electrical equipment to required for the installation, alteration ar repair of genera- <br /> approved permanently installed receptacles. tion, transmission, distribution, meterinb or otl�er related <br /> �a�; equipment that is under the ownership and control of public <br /> 1. Portable l��ating, cookin�or clothes dryin� appliances. service agencies by established right. <br /> 2. Replacement of any minor part that does not alter Rl(l5.3 Applieation for permit.To obtain a permit.the appli- <br /> . approval of equipment ormake such equipment unsafe. cani shall first file an applica�ion therefor in writing on a form <br /> 3. Portable-fuel-cell appliances that are not connected to a furnished by the department of building safety for thatpurpose. <br /> fixed piping system and are not interconnected to a �uch application shall: <br /> power grid. l. Identify and describe the worlc to be covered by the per- <br /> Mechanical: mit for which application is made. <br /> 1. Portable heating appliances. 2. Describe the land on which the proposed work is to be <br /> done by legal description, street address or similar <br /> ''. Portable ventilation appliances. � descrip�ion that will readily identify and definitely locate <br /> 3. Portable coolin� units. the proposed buildin�or work. <br /> 2006 If�➢TERNATIONAL R�SIDENTIAL COQ��' � <br />