• . ADMINlSTRATION
<br /> SECTION R1 Q5 4. Steam,hot or chilled water piping within any heating or
<br /> PERMITS coolin�equipment re�ulated by this code.
<br /> R1Q5.1 Required.Any owner or authorized agent who intends 5. Replacement of any minor part that does not alter
<br /> to construct, enlar�e, alter, repair, move, demolish or chanbe approva]of equipment or make such equipment unsafe.
<br /> the occupancy of a building or structure, or to erect, install,
<br /> enlarge,alter,repair,remove,convert or replace any electrical, 6. Portable evaporative coolers.
<br /> gas.mechanical or plumbing system, the ins�allation of which 7. Self-contained refrigeration systems containing 10
<br /> is re�ulated by this code,or to cause any such work to be done, pounds(4.54 k�)ar less of refrigerant or that are actuated
<br /> shall first make application to the building ofFicial and obtain by motors of 1 horsepower(746 W)or less.
<br /> the required permit. 8, portable-fuel-cell appliances that are not connected to a
<br /> R10�.2 Work exempt from permit. Permits shall not be fixed pipin� system and are not interconnected to a
<br /> required for the followinb. Exemption from permit require- power�rid.
<br /> ments of this code shall not be deemed to grant authorization
<br /> for any work to be done in any manner in violation of the provi- The stoppin�of leaks in drains,water,soil,waste or vent pipe;
<br /> sions of this code or any other laws or ordinances of this provided,however,that if any concealed trap.drainpipe,water,
<br /> jurisdiction. soil,waste or vent pipe hecomes defective and it becomes nec-
<br /> essar5�to remove and replace the same with new material,such
<br /> Building: work shall be considered as new work and a permit shall be
<br /> 1. One-story detached accessory structures used as tool and obtained and inspection made as provided in this code.
<br /> storage sheds,playhouses and similar uses,provided the The clearing of stoppa=es or the repairing of leaks in pipes,
<br /> floor area does not exceed 120 square feet(11.15 mz). valves or fixtures, and the removal and reinstallation of water
<br /> 2. Fences not over 6 feet(1829 mm)high. closets, provided such repairs do not invo]ve or require the
<br /> 3. Retaining walls that are not over 4 feet (]219 mm) in replacement or rearrangement of valves,pipes or fixtures.
<br /> hei�ht measured from the bottom of the footin�to the top Rl(l5.2.1 Emergency repairs. Where equipment replace-
<br /> of the wall,unless supporting a surcharge. ments and repairs must be performed in an emergency situa-
<br /> 4. Water tanks supported directly u}�on grade if the capacity tion, the permit application shall be submitted within the
<br /> does not exceed 5,000 gallons(l 8 927 L)and the ratio of next working business day to the building official.
<br /> hei�ht to diameter or width does not exceed 2 to 1. R1Q5.2.2 Repairs. Application or notice to the buildin�
<br /> � 5. Side�vall<s and driveways. ofFicial is not required for- ordina�y repairs to structares,
<br /> 6. Paintin�, papering, tiling, carpetin�, cabinets, counter replacement of lamps ar the connection of approved porta-
<br /> tops and similar finish work. ble electrical equipment to approved permanently installed
<br /> receptacles.Such repairs shall not include the cutting away
<br /> 7. Prefabricated swimming pools that are less than 24 of any wall,partition or portion thereof,the removal or cut-
<br /> inches(6l0 mm)deep. tinD of any structural beam or load-bearing support, or the
<br /> � 8. Swings and other playground equipment. removal or change of any required means oi egress,or rear-
<br /> 9. Window awnin�s supported by an exterior wall which rangement of parts of a structure affectinD the e�ress
<br /> do not project more than 54 inc}�es(1372 mm)from the requirements:nor shall ordinary repairs include addition to,
<br /> exterior wall and do not require additional support. alteration of,replacement or relocation of any water supply,
<br /> sewer, drainage,drain leader,gas, soil,waste,venl or simi-
<br /> Eiectrica�: ]ar piping, electric wiring or mechanical or other worlc
<br /> Repairs and maintenance: A permit sha11 not be required for affecting public health or general safery.
<br /> minor repair work, includin�the replacement of lamps or the R105.2.3 Public service agencies. A permit shall not be
<br /> connection of approved portable electrical equipment to required for the installation, alteration ar repair of genera-
<br /> approved permanently installed receptacles. tion, transmission, distribution, meterinb or otl�er related
<br /> �a�; equipment that is under the ownership and control of public
<br /> 1. Portable l��ating, cookin�or clothes dryin� appliances. service agencies by established right.
<br /> 2. Replacement of any minor part that does not alter Rl(l5.3 Applieation for permit.To obtain a permit.the appli-
<br /> . approval of equipment ormake such equipment unsafe. cani shall first file an applica�ion therefor in writing on a form
<br /> 3. Portable-fuel-cell appliances that are not connected to a furnished by the department of building safety for thatpurpose.
<br /> fixed piping system and are not interconnected to a �uch application shall:
<br /> power grid. l. Identify and describe the worlc to be covered by the per-
<br /> Mechanical: mit for which application is made.
<br /> 1. Portable heating appliances. 2. Describe the land on which the proposed work is to be
<br /> done by legal description, street address or similar
<br /> ''. Portable ventilation appliances. � descrip�ion that will readily identify and definitely locate
<br /> 3. Portable coolin� units. the proposed buildin�or work.
<br /> 2006 If�➢TERNATIONAL R�SIDENTIAL COQ��' �