Laserfiche WebLink
Aggregate Make-Up Air�lternative and Ventilation Documentation <br /> (Can be Used as Supplement to Permit Application) <br /> Bld Address: 1345 Rest point lane Date: 10/3/2005 <br /> Cit : Orono Zip Code: <br /> CaYI�.'�ed BY Je4f Scfiiec�e Ca Narre:Blala�&Aseocia�es <br /> Path 1, Aggregate Alternative Exhaust Devices cFnn <br /> Space Heater: Sealed Combustion Clothes Dry�r 150 <br /> Water Heater: Direct Verrted Kitchen Exhaust 600 <br /> Gas Hearth: Sealed Combustion Master Bathroom 70 <br /> Solid Fuel Hearth: None 2nd FI Ba�room 70 <br /> CO Alarm: Not Required 1 st FI Bathroom 70 <br /> Bsmt Bathroom 70 <br /> Make-Up Alr Requirements CeMralVacuum None <br /> Largest <br /> Exhaust Devices Dryer Kitchen Total <br /> Other <br /> Exhaust Capacity 150 600 70 820 <br /> Distribution CFM <br /> Passive Infiltration 175 <br /> Passive Opening(s) Rigid Flex Direct <br /> 390 10 11 9 <br /> Powered Make-Up <br /> 255 <br /> Ventilation Minimum Required <br /> Sq. Ft. Bedrms Total Ventilation People Ventilation Supplemental Ventilation <br /> 7006 5 350 90 260 <br /> People Supplemental <br /> HRV or ERV 1 90 cfm. HRV or ERV 1 100 cfm. <br /> Ceritral Exhaust 0 cfm. Central Exhaust 211 cfm. <br /> People: 90 cfm. Supplemental: 311 cfm. Total: 401 cfm. <br /> ��[� 1���1v.v � ��-�vs- � �.t'L -���G z <br /> Applicant(print name) Signature Date Phone number <br />