Laserfiche WebLink
. <br /> � RH A�-Resldentlml'&llght Commercial HV�1C Lqads Program Elt#e SQftware Developrraent,inc. ' <br /> ' We bume Ss�pply Inc: <br /> Ply� outh,MN 5544t '` fl9-17-20Q2 ' Page 7 <br /> Sy tem#12one#2 Summary'LoadB <br /> Component Area Sen. Lat. Sen. Total <br /> Description Quan Loss Gain Gain Gain <br /> 3A Window Double Pane Clear Glass Wood Frame 290 13,102 0 10,854 10,854 <br /> 10D Door Wood Solid Core 63 2,376 0 540 540 <br /> 12J Wall R-11 + R-8 Sheathing 1,170 4,798 0 1,089 1,089 <br /> Subtotals for structure: 1,523 20,276 0 12,483 12,483 <br /> Active People: 0 0 0 0 0 <br /> Inactive People: 0 0 0 0 0 <br /> Appliances: 0 0 0 0 0 <br /> Lighting: 0 0 0 0 0 <br /> Ductwork: 0 8,857 0 3,181 3,181 <br /> Infiltration: Winter CFM: 274.4, Summer CFM: 213.4 353 24,013 4,494 3,417 7,911 <br /> Ventilation: Winter CFM: 0.0, Summer CFM: 0.0 0 n/a n/a n/a n/a <br /> Sensible Gain Total: 19,081 <br /> Temperature Swing Multiplier: X1.00 <br /> Zone Load Totals: 53,146 4,494 19,081 23,575 <br /> Chec�k Figures '` <br /> Supply CFM: 894 CFM per square foot: 0.564 <br /> Square feet of room area: 1,585 Square feet per ton: 745.081 <br /> Zone�Loads <br /> Total heating required with outside air: 53,146 Btuh 53.146 MBH <br /> Total sensible gain: 19,081 Btuh 81 % <br /> Total latent gain: 4,494 Btuh 19 % <br /> Total cooling required with outside air: 23,575 Btuh 1.965 Tons (based on sensible+ latent) <br /> 2.127 Tons(based on 77%sensible capacity) <br />