My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
R
>
Rainey Road
>
2690 Rainey Road - 04-117-23-43-0016
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:14:45 PM
Creation date
7/16/2018 9:22:03 AM
Metadata
Fields
Template:
x Address Old
House Number
2690
Street Name
Rainey
Street Type
Road
Address
2690 Rainey Rd
Document Type
Septic
PIN
0411723430016
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> CITY�OF ORONO <br /> � � �� <br /> Municfipal Offices O O <br /> Post Office Box 66 <br /> Crystal Bay, MN 55323-0066 � � ON—SITE SEWA(�E TREATM81�1'1' <br /> ,� � INSPECTION REPORT <br /> ti <br /> ! ��9k'ESH.�g'�G <br /> r <br /> � /� <br /> Owner:� )'1 � Address• � <br /> Permit #'e: �'l7 Dates:��b� Contractors: <br /> City ordinande number 100;requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The on-site sewage treat�ent system at the above address has been inspected and appears to fall into the category <br /> checked beloN. <br /> (This is � an existing system [ ) new construction) <br /> SYSTEM CONfO ITY 1-3 : <br /> 1 "COD� SYSTEM"-A system which meets all the Location, design, and construction standards of the current City <br /> (�odes, and whi�ch is operating satisfactorily by treating and disposing of the entire current sewage input <br /> ithout discharging any pollutants dnto ground or surface waters. <br /> 2 "CON�ORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the <br /> rrent City Codes, but was installed according to the code in effect at the time of installation, and which <br /> s operating satisfactority by treating and disposing of the entire current sewage input without discharging <br /> y pollutants into ground or surface Waters. <br /> 3 "NON C�IFORMING SYSTEM"-A prohibited 'system; a system located within a designated 100-year floodplain; any <br /> stem which nay or may not meet pll the location, design, and construction standards of the current City <br /> �des and whiah is failing tor any reason; and any.system with less than 3 teet of unsaturated soil or sand <br /> qetween the d�stribution device and the limiting soil characteristics. <br /> �The limiting soil characteristic �j�1 has or [ ] has not been identified at this time. If the limiting soil <br /> haracteristic has not been identifiied, this classification may be subject to revision.> <br /> TANK CONDITIr 5-10 : � <br /> yanJc inspect`ion indicates: <br /> (_j� Purtipou� not needed mt this time. <br /> 6 Solids eccumulation in tanks indicates they should be rxmped out this year to help prevent future problems. <br /> 7 Solidsfaccunulation in tanks is at a critical level. Tanks should be punped out as soon as possible. <br /> 8 Systembis discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar�e. <br /> 9 Inspec�ion risers missing-tanks could not be inspected. lnspection risers (4" dia. pipe) �st be installed in each <br /> lank at next pumpout. [f tanks have not been pumped out within the last three years, they should be punped <br /> but now. <br /> 10 Inspedtion pipe is located directly over tank baffle (does not give accurate measurement of solids accunulation). <br /> If tanks have not been punped out rithin the last three years, they should be pumped out now. <br /> DRAI FIELD DIT10N 11-14 : <br /> D�field nspection indicetes: <br /> 1 Drain eld is dry, no surfacing evident. <br /> Sane idence of surfacing, not critical yet. <br /> 13 Drain ield is saturated and visibly di�charging untreated etfluent to the surface. Contact the City [nspector <br /> �mmediately. Repairs must be comp eted within 90 days. <br /> 14 DrainfEield extent and condition unknown. <br /> LIM1 ING SI E FACTORS s o setbacks etc. : <br /> POTENTIAL F�R SYSTEM FAiI�URE (depends on soils,water table,etc.): L�/ <br /> h <br /> COM�IENTS� <br /> Date of Inspection tic System inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, advised that this report does not guarantee or certify that an existing system will continue to function <br /> properlyi t is merely an opinion of the adequacy of the system under current conditions based on the availabte <br /> i nf armat i or�. <br /> ' This report must be kept on the premises with the system locetion and punping records. <br /> ; WHITE COPY/Inspectors Flle YELLOW COPY/Homeowner <br /> [ <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.