My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1996-007924 - new septic system
Orono
>
Property Files
>
Street Address
>
R
>
Rainey Road
>
2685 Rainey Road - 04-117-23-43-0013
>
Septic
>
1996-007924 - new septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:14:36 PM
Creation date
7/16/2018 9:10:05 AM
Metadata
Fields
Template:
x Address Old
House Number
2685
Street Name
Rainey
Street Type
Road
Address
2685 Rainey Rd
Document Type
Septic
PIN
0411723430013
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�� S—P � EST1'ING, INC. Ste�en B. Schirmers — MPCA Cert. Na. 627 <br /> ` ` ' 951 Katydid Lane NE • St. Michaei, MN 55376 • (612) 497-3566 <br /> May 16, 1995 <br /> Sue Vi kerman <br /> 26�5 R�iney Rd� <br /> Orono, iHenn. C . , MN <br /> � <br /> � <br /> This 0�-Site S wage Treatment System is Designed for a Type 1, four <br /> bedroo home D signed in accordance with the Minnesota Pollution <br /> Contro� Agency Chapter 7080 and local ordinances . <br /> The soils on tlhis site are a clay loam. A seasonally high water <br /> table �vas located at 12" to 24" , (mottled soil ) . Due to the <br /> seasondlly hig� water table, a Pressurized Mourid System will need <br /> to be installed for adequate treatment of septic effluent. <br /> This site has �n exsting trench system which is less than 3 ' from <br /> the se3�sonally high water table & the bottom of the system. A <br /> boring ; into th� system indicated the system is also hydraulically <br /> overlo�ded. T�e system is Non-Conforming. <br /> The so�ls at a� depth of 12" have a percolation rate averaging <br /> 12. 2 min/inch. ; <br /> A pumping cham�er will need to be installed to lift the effluent <br /> to the treatme�t area. <br /> The manifold and supply line pipe must have back drainage to the <br /> pumping chambeX. The distribution pipes shall have their ends <br /> capped. Be sure the rock and sand fill material are clean. The <br /> sod layer beloW the entire mounded area must be �urned over, just <br /> break up the sbd, be sure not to over work. <br /> The power supply and switches must be located outside the manhole <br /> and pumping chamber in a weather proof enclosure. A warning device <br /> must be installed with a light and sound device, this is in case of <br /> a pump failure;. <br /> All neighborinig wells are located greater than 100 ' away from the <br /> propos�d treatment area. <br /> 1 <br /> � <br /> � CONT' D <br /> ; � . <br />
The URL can be used to link to this page
Your browser does not support the video tag.