Laserfiche WebLink
► <br /> i � <br /> I CITY OF ORONO �I � � <br /> Municipal Offices � O O <br /> ! Post Offi e Box 66 <br /> C ystal Bay, M 55323-0066 � � ON—SITE SEWAC4E TREATI�NT <br /> f I r�,, � INSPECTION REPORT <br /> � i � <br /> � ! ' ��9k'ESH�4'�G <br /> Own I r• I I 11 Addres s• <br /> i � <br /> ! Per it �'s: Dates� �il�J"71� Contractors: f4/1 �P� LS/[J�• <br /> ' City rdinence n r 100 requires tha�� each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The -site sewag treatment system a� the above address has been inspected and appears to fall into the category <br /> check below. <br /> ' (7his is U] an existing sysi,Rem [ ] new construction) <br /> �.� <br /> SYSTE CONFORMITY 1-3 : <br /> 1 "CODE SYST M"-A system which me�ts all the location, design, and construction standards of the current City <br /> � Codes, nd which is operati satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any poll��itants into ground or surface waters. <br /> I 2 � "CONFORMIN SYSTEM°-A system wF�ich does not meet all the location, design, and construction standards of the <br /> � current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is oper ting satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> � any pol utants �nto ground oh surface waters. <br /> '�NON-CONFO MING SYSTEM"-A proh�bited system; a system located within a designated 100-year floodplain; any <br /> � system hich �y or may not; meet all the location, design, and construction standards of the current City <br /> Codes a�id which is failing for any reason; and eny s stem with less a <br /> between the distribution devi ce and t e limiti c arac er�s �cs. L <br /> ��1� �� �I <br /> I <br /> (The li iting soil characteristic has or [ ] has not been identified 8t this t . If the limiting soil <br /> � charact ristic has not been identi�ed, this classification may be subject to revision.) _ <br /> q <br /> TANK C �NDITlON 5-1 : <br /> Tank i spection ind cates: <br /> 5 umpout not n eded at this time. <br /> 6 lids accunu ation in tanks indicates they should be punped out this year to help prevent future problems. <br /> 7 lids accunu ation in tanks is at :a critical level. fianks should be pumped out as soon as possible. <br /> stem is dis harging to the surfage. Tanks must be punped out within 48 hours to eliminate surface dischar�e. <br /> � spection ri ers missing-tanks coWld not be inspected. Inspection risers (4" dia. pipe> must be installed in each <br /> tank at next Ex.mpout. lf taN�ks have not been punped out within the last three years, they should be puiped <br /> out now. <br /> 10 nspection pi is located directl over tank baffle (does not give accurate measurement of solids accimulation). <br /> � If tank have not been out within the last three years, they should be punped out now. <br /> I , <br /> I <br /> DRAiNF LO CONDITIO! 17-14 : <br /> D f eld inspectidn indicates: <br /> 1 D ainfield is ry, no surfacing evident. <br /> ' �S evidence f surfacing, not critical yet. <br /> 13 rainfield is saturated and visib�y discharging untreated effluent to the surface. Contact the City Inspector <br /> immediat ly. Repairs must be,,completed uithin 90 days. <br /> 14 D ainfield ext nt and condition unk�own. <br /> ILIMITI SITE FACTOR slo setbacks etc�l : <br /> �POTENTI L FOR SYSTEM fA1LURE de nds on oils water table etc. : �'��� <br /> I <br /> �COMME TS: <br /> , � Da e o inspectior� e ic System inspector <br /> i <br /> Note: n the event hat this inspection fieport is used to satisfy the requirements for a mortgage or other transfer of <br /> �ropert , be advised that this report dols not guarantee or certify that an existing system will continue to function <br /> roperl i but is me ely an opim on of the adequacy of the system under current conditions based on the evailable <br /> nforma ion. <br /> ; i <br /> Thi� report must be kept on the pretnises with the system locetion and pumping records. <br /> � � WHITE COPY/Inspectars Flle YELLOW COPY/Homeowner <br /> i 1I� I <br />