Laserfiche WebLink
i <br /> On the North Sbore o f <br /> Lake Minnetonka <br /> ON-SITE SEWAGjE TREATMENT <br /> INSPECTIOI�I REPORT � POST OFFICE BOX 66 <br /> � _ � � 1335 S. Brown Rd. <br /> Crystal Bay, MN 55323 <br /> 473-7357 <br /> OWNER ✓� h �� ��� ADDRESS ��VC, S,�7�1 �• N <br /> PERMIT NO.'S. g� DATES /'� b z CONTRACTORS •�� �� <br /> City Ordinance No.210 requires that each on�ite sewage treatment system in Oro�o be inspected on a regular basis.The onsite sewage <br /> treatment system at the 8bove address has been i�spected and appears to fall into the category checked below. <br /> (This is�-an existiog system ❑ new construction) <br /> �� Meets ar exceeds current City standards in ali respects relating to design,construction,and location.Appears to be operating <br /> properly. <br /> � 2 Does n0t meet all current City standards for new construction (1878 Code) but in most respects appears to be designed, <br /> locateda and co�structed generally in accordance with previous codes.System appears to be functioning properly;no major <br /> upgrading of the system ia required at this time. <br /> � 3 Does nqt meet current City standards in many respects relating to design,construction,or locatio�.Appears to be operating <br /> adequat�ly at this time,but has a relatively high potential for future problems. No major up9rading of system is required at <br /> this tim . <br /> � 4 System may or may not meet current City standards for design,construction or location,but is failing to properly treat and <br /> dispose bf the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is <br /> creating,a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ <br /> replac;err'ent procedures. If drainfietd replacement is necessary,soil testing will usually be required,and a design and site plan <br /> must be submitted for review.Your contractor must obtain a permit before work is started. <br /> SYSTEM CONDITION (� Checked items may require your action) <br /> Tank inapection indicatest •�'Inspection pipe is located directly over tank baffle.(Does not <br /> ❑ Pumpout not needed at this time. give accurate measurement of solids accumulationJ If tanks <br /> ❑ Solids aecumulation in tanks indicetes they should be pump- have not been pumped out within the last three years,they <br /> ed out this year to help prevent future problems. should be pumped out now. <br /> ❑ Solida accumulatidn in tanks ia at a critica� level, Tanks Drainfield inspectio�indicates: <br /> ahould be pumped put as soon as pouible. �-Drainfield ia dry,no surfacing evident. <br /> ❑ System ia discharging to aurface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. <br /> within 48 hours to�liminate surface discharge. ❑ Orainfield is saturated and visibly discharging untreated <br /> ❑ Inspection risers jnissing—tanks could not be inspected. effluent to the surface. This condition may require replace- <br /> Inspection risera (4"dia. pipe)muat be installed in each ta�k ment or edditions to drainfield. Contact the City Inspector <br /> at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. <br /> the last three years,they should be pumped out now. � Drainfield extent and condition unknown. <br /> SITE CHARACTERISTIC$: <br /> Limiting Site Factors Potential for System Failure Site Capabilities for <br /> ❑ Slope (depends on soil types,water Futu e Expansion <br /> ❑ Soil table and system condition) Adequate <br /> ❑ High water table �Low Fair <br /> D Lot size ' ❑Medium O Poor <br /> ❑ Lake,wetland,or stream ❑ High � Inadequate <br /> ❑ Drainage ❑System is causing visible <br /> surface discharge. / <br /> COMMENTS:� � Q- <br /> n�� QI <br /> ��I <br /> Date of Inspection eptic System Inspector <br /> Note: In the event that thi6 inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that <br /> this report dces not guaranRee or certify that an existing syster�► will continue to function properly,but is merely an opinion of the adequacy <br /> of the system under current,conditions based on the available information. <br /> � This report must be kept on the premises with system location and pumping records. <br /> WHITE COPY/I�spector's File GOLD COPY/Homeowner <br />