My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info-including design for general purposes only
Orono
>
Property Files
>
Street Address
>
P
>
Pine View Drive
>
1150 Pine View Drive - 28-118-23-42-0009
>
Septic
>
septic info-including design for general purposes only
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:25:42 PM
Creation date
7/9/2018 11:05:54 AM
Metadata
Fields
Template:
x Address Old
House Number
1150
Street Name
Pine View
Street Type
Drive
Address
1150 Pine View Dr
Document Type
Septic
PIN
2811823420012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSPECTOR CHECKLIST - mound <br /> 11�U i'lne Vlew Urne <br /> � WELL setbacl:s: 20'to pressure tested sewer line (5 psi for 15 min) <br /> 50'to everythin� 100'to dispersat area with shaltow welt <br /> PROPERTY LINES setback: 10'to everything <br /> Road setback: platted: 10'prop line. Metes &bounds: out of road easement, or outer ditch. <br /> LAKE/BLtiFF secback: 20'for bluff. Lakes: GD_, RD_, NE Protected wettand_. <br /> Auilding setbacks: 10'for everything, 20'for dispersal area. <br /> WATER LINE under pressure se 10'to bed,tank 8 sewer line. (else sewer line> 12"below} <br /> � Sewer line�t baffle connection (no 90's, 3'between 45's, slope min 1'in 8', max 2"i�8') <br /> (no depth req's, ctean out every 100', Sch 40 pipe) <br /> � Septic tank and risers (water tight, insulated, proper depth, existing verified by pumpin�) <br /> mfg 2250 gallons none <br /> Rise�over outlet, riser over inlet or center, and 6"+inspection pipe over any remaining baffles. <br /> No effluent filter&alarm <br /> Dose tank risers and piping {water tight, insulated, proper depth, drainback) <br /> mfg 1300 gallons <br /> � dose pump 38 gpm 19 head VERIFY PUMP CURVE 5.3 min ON 9 hr OFF <br /> � float setting drop 7.8 inthes at 25.5 gpi "DESIGNED" 4.9 inches approx float tether length <br /> 200.0 gal dose divided by gpi "INSTALLEO"= inches float drop (field corrected <br /> LABfL pump requirements and drawdown on riser or panet <br /> Cam lock reachable from grade- 30"max. J-hook weep hote. Suppty tine access (no hard 90's) <br /> 2.0 inch supply pipe; Sch40, sloped 1/8"+, supported by 4"sch40 sleeve or compacted, and buried 6"+, <br /> splice box / controt panel/ electrical connections <br /> flow measurement: CT, ETM, time dosed, home water meter <br /> mound absorption area rough up <br /> mound rock dimensi�ns 10.0 X 31.3 <br /> Sand lift depth 20 inches. (Jar test: 2"sand leaves< 1/8"silt after 30 min) <br /> � Absorption Sand beyond rock 0.0 upstope 10.0 downslope <br /> � Bermed topsoil beyond rockbed 0 upslope 12 sideslope 20 downslope <br /> cover depth of 12-18"+ VERIFY <br /> 3 laterals {1-2'from edge of rock) <br /> 2.00 inch pipe size (Sch40 pipe&fittings) <br /> 3.0 ft lateral spacing <br /> 8 7/32 inch perforations <br /> 3.0 ft perforatlon spacing <br /> Air inlet at end of taterals, and at top feed manifold if necessary. VERIFY <br /> clean outs (no hard 90's) <br /> 4'inspection pipe to bottom of rock, anchnred VERIFY <br /> Abandon existing system -if necessary �Re-use existing tank certification <br /> monitorfng plan and type <br /> well abandonment form •if necessary <br />