My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info-including design for general purposes only
Orono
>
Property Files
>
Street Address
>
P
>
Pine View Drive
>
1150 Pine View Drive - 28-118-23-42-0009
>
Septic
>
septic info-including design for general purposes only
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:25:42 PM
Creation date
7/9/2018 11:05:54 AM
Metadata
Fields
Template:
x Address Old
House Number
1150
Street Name
Pine View
Street Type
Drive
Address
1150 Pine View Dr
Document Type
Septic
PIN
2811823420012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
201 P°����� Mound Design <br /> www.Septtd2esource.com (ve�s 15,2) <br /> Property Owner: Stonewood LLC Date: 4/10/2017 <br /> Site Address: 1150 Pine View Drive PID: 2811823420009 <br /> Comments: Down Slope Rock Bed <br /> instructions: � _�nter data Q =ad3ust if desired � = computer calculated • DO NOT CHANGE! <br /> i� �? bedroom Type � Residentiat System <br /> �► 375 GPD desigh flow <br /> 3� Yes Garbage d�sposal or pumped to septic 5096 larger tank with multiple comp/tanks <br /> o� �Gal Septic tank(code minimum) 2250 Gat Septic tank(design size / �UG req'd) <br /> Tank options: none <br /> s3 1.2 GPD/ft�mound sand ioading rate contour loading rate of 12 req's a min 31.3 ft. long rockbed <br /> e� 10.0 ft rockbed width 31.3 ft rakbed length <br /> » 3.0 ft lateral spacing 3.0 ft pertoration spacing (maximum of 3 for both) <br /> end feed manifold connection <br /> s� �lateraEs 29.3 feet long 10.0 perfs / lateral 30 perfs total <br /> (1/2 a perf m�ans the first pert starts at the middle feed manifotd) <br /> 9, 7/32 inch perfs at 1�feet residual head gives 0.56 gpm flow rate per pertoration <br /> for this perf size Fs spacing, & pipe size on tine 12, max perfs/lateral= �, line#8 must be less--> OK <br /> to� 4.0 doses per day (4 minimum) <br /> >>> �gallons per dose (Veatment valume) <br /> 2.00 5x <br /> ia� 2.00 inch diameter laterals must be used to meet"4x pipe volume"requirement <br /> 2.00 3x <br /> �3� 73 feet of 2.0 inch suppty line leads to 12 galtons of drainback voiume <br /> (Tip: "top feed"manifold to controt the drainback) <br /> �a� 200 gallons TOTAL pump out volume (treatment+drafnback) <br /> �s� 10 feet vertical lift from pump to mound laterals, leads to a: <br /> �6; 38 GPM @ 19 feet of head, Pump requirement (note: >50gpm may require an extra 3-6'of head) <br /> i�, 375 gal Dose Wnk (code minimum) 1300 gal Dose tank(design size / LUG req'd) at 25.49 gpi <br /> leads to a <br /> �s► 7.8 inch swing on Demand float, or timed dosing of 5.3 min ON (confirm pump rate with drawdown <br /> (this delivers Average flow, �70%of Peak design flow)e9 hrs OFF test and adjust as necessary) <br /> i9� 12 inches from bottom of tank to"Pump OFF'ftoat <br /> ao; 20 inches from bottom of tank to"Pump ON"float, or 12 inches to'Timer ON"ftoat if time dosed <br /> ai� 23 inches from bottom of tank to"Hi LeveC float, or 33 inches to"Hi LeveC float if time dosed <br /> 2?� 714 galtons reserve capacity (after High Levet Alarm 3s activated) <br />
The URL can be used to link to this page
Your browser does not support the video tag.