My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic design-general approval only
Orono
>
Property Files
>
Street Address
>
P
>
Pinehurst Court
>
650 Pinehurst Court - 06-117-23-34-0006
>
Septic
>
septic design-general approval only
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:27:23 PM
Creation date
7/9/2018 9:13:07 AM
Metadata
Fields
Template:
x Address Old
House Number
650
Street Name
Pinehurst
Street Type
Court
Address
650 Pinehurst Ct
Document Type
Septic
PIN
0611723340006
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2011 purplecode Mound Design <br /> www.SepticResource.com (vers 15.2) <br /> Property Owner: Norton Homes Date• 2/1/2018 <br /> Site Address: 650 Pinehurst Court Plp; Q611723340006 <br /> Comments: Future site <br /> instructions: � =enter data � =adjust if desired � = computer calculated - DO NOT CHANGE! <br /> i� �bedroom Type � Residential System <br /> �� 750 GPD design flow <br /> 3� Yes Garbage disposal or pumped to septic 50%targer tank with multiple comp/tanks <br /> -t, 2250 Gal Septic tank (code minimum) 2250 Gat Septic tank (design size / LUG reqd) <br /> Tank options: none <br /> >> �•2 GPD/ftz mound sand loading rate contour toading rate of 12 req's a min 62.5 ft. long rockbed <br /> h; 10.0 ft rockbed width 62.5 ft rockbed length <br /> �, 3A ft laterat spacing 3.0 ft perforation spacing (maximum of 3 for both) <br /> end feed manifold connection <br /> �� �3 laterats 60.5 feet long 21.0 perfs / lateral 63 perfs totat <br /> (1/2 a perf ineans the first perf starts at the middle feed manifold) <br /> �>� 7/32 inch perfs at �1 feet residual head gives 0.56 gpm flow rate per perforation <br /> for this perf size £x spacing, �x pipe size on line 12, max perfs/laterat = 30 , tine#8 must be tess --> OK <br /> i�>> 4.0 doses per day (4 minimum} <br /> �i, 188 gallons per dose (treatment volume) <br /> 2.00 5x <br /> i�� 2.00 inch diameter laterals must be used to meet"4x pipe volume" requirement <br /> 2.00 3x <br /> i�� �feet of 2.0 inch supply tine leads to ##### gallons of drainback volume <br /> �Tip: "top feed" manifold to control the drainback) <br /> ia� ###t�## gallons TOTAL pump out volume (treatment+drainback) <br /> i>� feet vertical lift from pump to mound laterals, leads to a: <br /> i��� 36 GPM C� ###tt# feet of head, Pump requirement (note: >50gpm may require an extra 3-6'of head) <br /> i�� 750 gat Dose tank(code minimum) 750 gat Dose tank {design size / LUG req'd) at �gpi <br /> teads to a <br /> isi ##�##�# inch swing on Demand float, or timed dosing of ##### min ON (confirm pump rate with drawdown <br /> (this delivers Average flow, =70%of Peak design flow) ##### hrs OFF test and adjust as necessary) <br /> i��, 12 inches from bottom of tank to"Pump OFF"float <br /> ��n ###### inches from bottom of tank to"Pump ON"float, or 12 inches to"Timer ON"ftoat if time dosed <br /> �i� �###### inches from bottom of tank to"Hi Level"float, or ###I#�t inches to"Hi Level"float if time dosed <br /> ��i �#####gallons reserve capacity tafter High levet Alarm is activated) <br />
The URL can be used to link to this page
Your browser does not support the video tag.