-_____ _ _ -- ------ - _ _ _ __- -- -- __ _ <br /> Rhvac-Residential 8�Light Commercial HVAC Loads Elite Software Development,Inc. <br /> Sabre Plumbing&Heatinq � 600 Pinehurst Court Orono <br /> Plymouth MN 55447 _____ _ __ Pa e 4 <br /> Total Building Summary Loads <br /> Component Area Sen Lat Sen Total <br /> Descri tion Quan Loss Gain Gain Gain <br /> Low EE: Glazing-LowEE Builder Grade .31 U-value, .29 811.5 21,888 0 21,859 21,859 <br /> SHGC, Window and Patio Door, u-value 0.31, SHGC <br /> 0.29 <br /> LOW EE: Glazing-Builder Grade Low E Windows& 114.2 3,181 0 2,945 2,945 <br /> Sliding Door .32 U value .30 SHGC, u-value 0.32, <br /> SHGC 0.3 <br /> 11J: Door-Metal - Fiberglass Core 69.3 3,620 0 999 999 <br /> 15A-10sffc-8: Wall-Basement, concrete block wall, R-10 1026 4,072 0 91 91 <br /> foam board to floor, no framing, no interior finish, <br /> filled core, 8'floor depth <br /> 15A-10sffc-4: Wall-Basement, concrete block wall, R-10 172 748 0 0 0 <br /> foam board to floor, no framing, no interior finish, <br /> filled core, 4'floor depth <br /> R20 12F-Osw: Wall-Frame, Custom, R-20 Insulation in 3324.7 19,088 0 2,917 2,917 <br /> 2x6 Cavity, no board insulation, siding finish, wood <br /> studs <br /> RJ 20 Spray Foam: Wall-Frame, Custom, Rim Joist R-20 583.5 2,540 0 716 716 <br /> Closed Cell Spray Foam <br /> R-20 12F-Osw: Wall-Frame, Custom, no board insulation, 1253.2 7,196 0 1,100 1,100 <br /> siding finish, wood studs <br /> R49 16B-49: Roof/Ceiling-Under Attic with Insulation on 2543 5,089 0 2,807 2,807 <br /> Attic Floor(also use for Knee Walls and Partition <br /> Ceilings), Custom, R-49 Blown Insulation, No <br /> Radiant Barrier, Vented Attic, Asphalt Shingles <br /> R49- 16B-49: Roof/Ceiling-Under Attic with Insulation on 624 1,249 0 689 689 <br /> Attic Floor(also use for Knee Walls and Partition <br /> Ceilings), Custom, R49 Blown Insulation-vented <br /> attic, asphalt shingles <br /> 21A-20: Floor-Basement, Concrete slab, any thickness, 2 1624 3,815 0 0 0 <br /> or more feet below grade, no insulation below floor, <br /> any floor cover, shortest side of floor slab is 20'wide <br /> 20P-30: Floor-Over open crawl space or garage, Passive, 651 1,982 0 182 182 <br /> R-30 blanket insulation, any cover <br /> 21A-20-c: Floor-Basement, Concrete slab, any thickness, 624 1,466 0 0 0 <br /> 2 or more feet below grade, no insulation below floor, <br /> carpet covering, shortest side of floor slab is 20'wide <br /> Subtotals for structure: 75,934 0 34,305 34,305 <br /> People: 6 1,200 1,380 2,580 <br /> Equipment: 901 4,116 5,017 <br /> Lighting: 1250 4,263 4,263 <br /> Ductwork: 5,246 474 1,189 1,663 <br /> Infiltration: Winter CFM: 129, Summer CFM: 0 12,001 0 0 0 <br /> Ventilation: Winter CFM: 213, Summer CFM: 213 7,911 4,942 1,182 6,124 <br /> Humidification (Winter) 24.44 gal/day : 8,961 0 0 0 <br /> AED Excursion: 0 0 4,903 4,903 <br /> Total Building Load Totals: 110,053 7,517 51,337 58,854 <br /> Check Fi ures <br /> Total Building Supply CFM: 2,342 CFM Per Square ft.: 0.365 <br /> Square ft. of Room Area: 6,415 Square ft. Per Ton: 1,308 <br /> Volume (ft') of Cond. Space: 63,680 <br /> Bu_ilding Loads <br /> Total Heating Required Including Ventilation Air: 110,053 Btuh 110.053 MBH <br /> Total Sensible Gain: 51,337 Btuh 87 % <br /> Total Latent Gain: 7,517 Btuh 13 % <br /> Total Cooling Required Including Ventilation Air: 58,854 Btuh 4.90 Tons (Based On Sensible + Latent) <br /> M:\Sales and Estimating\Heat Calcs\Gonyea\600 Pinehurst Court Orono LEE.rh9 Friday, May 05, 2017, 9:10 AM <br />